Master Wall DPR Acrylic Superior Finish
Master Wall DPR Acrylic Superior Finish
Master Wall DPR Acrylic Superior Finish
Master Wall DPR Acrylic Superior Finish
Master Wall DPR Acrylic Superior Finish

Master Wall DPR Acrylic Superior Finish

Regular price $64.99 Sale

To finish strong you need a Superior Finish. Master Wall finishes have one of the highest 100% acrylic polymer contents in our industry. This translates to extra durability, lower life-cycle maintenance and a longer lasting finish.

  • 100% Acrylic Polymers for durability
  • Dirt Pickup Resistant (DPR) Polymers
  • Quartz or Marble aggregate available
  • 64 Standard Colors
  • Custom color matching available
  • DuroTone colorfast pigments, mildew enhancement, Silicone Coat additive options available
  • Vapor Permeable – resists blistering and allows trapped water vapors to pass
  • Low VOC—Suitable for Interior Use
  • Water Based – easy clean up with water

PRODUCT DATA SHEET

SDS (ENGLISH)      SDS (SPANISH)

Coverage per pail (sf/sm)*

Perfect Swirl 2.0, 120-150 (11-14)
Fine Sand 1.0, 160-170 (15-15.8)
Medium Sand 1.5, 130-150 (12-14)
Versatex 0.5, Varies with Texture

*All coverage is approximate and depend upon substrate, details and individual application technique.

Packaging/Shelf Life/Storage

Packaging: 5 gallon (19L) pail

Shelf Life: 2 years

Storage: Protect from extreme heat 90°F (32°C), freezing and direct sunlight.

Technical Data

ASTM B117 Salt Spray Resistance – Pass 300 Hours

ASTM C67 Freeze/Thaw – Pass 10 Cycles

ASTM C297 Tensile Bond – 30 psi minimum

ASTM D968 Abrasion Resistance – Pass 500L

ASTM D2247/E2570 Water Resistance – Pass 14 Days

ASTM D3273 Mildew Resistance – Pass 28 Days

ASTM E84 Surface Burning – Pass, FS=0, SD=0

ASTM E 96 Vapor Permeability – Pass, 12 perms, vapor open

ASTM E108 Flame Propagation – Pass

ASTM E2485/2570 (formerly EIMA 101.01) Impact Resistance – Pass

ASTM G23/G154/G155 Accelerated Weathering – Pass 2000 Hours

ASTM G53 Accelerated Weathering – Pass 2000 Hours

Hazard: This chemical is not considered hazardous according to the OSHA Hazard Communication Standard 2012 (29 CFR 1910.1200).

VOC: Less than 50 g/L.
Recycled Content: 0%

Application Temperature: 40°-110°F (5°-43°C)

Working Time: 1/4 hr

Set Time: 8-12 hrs

Dry Time: 48-72 hrs

at room temperature, working and drying time will vary with temperature and humidity

Approved Substrates

  • Master Wall Base Coats
  • Stucco
  • Prepared & Base Coated Surfaces of:
    • Brick
    • Concrete
    • Masonry
  • Others approved in writing

Application Procedure

Job Conditions – Air and substrate temperature for application of Superior Finishes must be 40°F (5°C) or higher and must remain 40°F (5°C) or higher for a minimum of 24 hours. Provide temporary protection to protect the wall system from damage until permanent flashings, caps and sealants are installed. Store materials within prescribed temperature limits and out of direct sunlight. High temperatures will reduce working times, Low temperatures and/or high humidity and pigment loading will extend working, set and dry times.

Preparation – The substrate must be approved by Master Wall Inc.®, clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents and curing compounds or anything that would affect bond. Painted surfaces are not acceptable and must be removed. Concrete and surfaces should cure for a minimum of 28 days. Stucco should be cured until clean, dry and hard—typically 14 days with a pH of 10 or less (13 or less if Primecoat Primer is used).

Interior drywall should be finished and made ready for paint. Prime surfaces with Primecoat/Sanded Primecoat primer prior to finishing.

Base Coats – Must be flat, dry hard, and free of efflorescence. Master Wall® base coats must cure a minimum of 12 hours before application of Superior Finish. Substrates of brick, masonry or concrete should be leveled smooth using either Master Wall® base coats or stucco.

Mixing – Thoroughly stir Superior Finish using a heavy duty 1/2” drill at 400 – 500 rpm and a heavy duty mixing paddle. Small amounts of clean, potable water may be added to obtain a workable consistency. To avoid color variations, add the same amount of water to each pail. Do not exceed 24 ounces (0.7L) of water per pail of finish.

Application — Apply a uniform thickness (about 1/16”) of Superior Finish to the substrate using a stainless steel trowel. Spread evenly and then scrape the finish coat down to a thickness no greater than the largest aggregate in the material. Immediately float the finish coat using a plastic float to the desired texture. Always maintain a wet edge to achieve uniformity of texture and color. Allow the finish to fully dry and set before exposure to inclement weather.

For Professional Results

  • Apply finish coats away from direct sunlight. Cold joints or color variations can occur if the finish dries too quickly.
  • Priming stucco surfaces with Primecoat/Sanded Primecoat evens out finish absorption and should be strongly considered and specified for dark colored finishes, especially those using Ultra Deep Base (UDB) tint base and over stucco to avoid efflorescence blush. Under certain conditions dark colors may show efflorescence on the surface during the cure process.
  • Surfaces exposed to the weather must be sloped (6:12 minimum).
  • Use of dark colors in high temperature climates can affect the performance of the system, especially EIFS and areas may need to be limited.
  • Deep, intense colors should be specified with DuroTone pigments to maintain colorfastness longer. Verify specialty colors with your Master Wall® Distributor.
  • Finishes are intended for the approved substrates listed above and should not be applied directly to gypsum board or insulation board products.

Clean Up—Tools and equipment can be cleaned with soapy water while the Superior Finish is still wet.

Information contained in this product data sheet conforms to the standard detail recommendations and specifications for the installation of Master Wall® Inc. products and is presented in good faith. Master Wall® Inc. assumes no liability, expressed or implied as to the architecture, engineering, or workmanship of any project. This information may be concurrent with, or superseded by other applicable documents, such as specifications and details. Contact Master Wall® Inc. for the most current product information.